19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 409: Congestion Query Test (#600) 2 of 2<br />

Error<br />

Code<br />

1<br />

2<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL The buffer level is nearly exhausted.<br />

The circuit pack is congested <strong>and</strong> no buffers are available.<br />

1. Retry comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If comm<strong>and</strong> continues to fail, examine the C-LAN or VAL port<br />

measurements to determine which ports are heavily utilized <strong>and</strong><br />

the processor occupancy of the circuit pack.<br />

Low processor occupancy when the circuit pack is congested indicates<br />

circuit pack failure.<br />

1. If the problem persists, reset the circuit pack with<br />

reset board location.<br />

2. If congestion recurs, replace the circuit pack.<br />

High processor occupancy indicates the circuit pack is congested due to<br />

traffic load.<br />

1. To relieve congestion in the short term, selectively busyout ports<br />

with busyout port location on the circuit pack.<br />

2. To achieve a more permanent resolution for CLAN-BD circuit<br />

packs, it may be necessary to move ports on this circuit pack to<br />

other Control LAN circuit packs. For VAL-BD circuit packs, it may<br />

be necessary to reassign announcements to other integrated<br />

announcements circuit packs.<br />

3. Consider replacing affected ports with new ports.<br />

3 FAIL The circuit pack is not operating normally <strong>and</strong> is congested.<br />

1. Replace the circuit pack.<br />

PASS Hardware setting <strong>and</strong> attached cable type match circuit pack<br />

administration, <strong>and</strong> no <strong>error</strong>s are detected.<br />

1390 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!