Table 422: BRI Remote Loopback Test (#627) 2 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

BRI Remote Loopback Test (#627)<br />

1139 ABORT The PN’s packet bus is out-of-service.<br />

1. Follow the repair procedures for the packet bus.<br />

2. After completing step 1, enter <strong>test</strong> port long location, <strong>and</strong><br />

review the results of the BRI Port Local LAN Looparound Test<br />

(#618) to verify the repair.<br />

1144 ABRT The PPN’s packet bus is out-of-service.<br />

1. Follow the repair procedures for the PPN’s packet bus.<br />

2. After completing step 1, execute <strong>test</strong> port long PCSSpp, <strong>and</strong><br />

review the results of the BRI Port Local LAN Loop Around <strong>test</strong><br />

(#618) to verify the repair.<br />

1187 ABORT The circuit pack, port, or station may have been busied out by a<br />

technician.<br />

1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD,<br />

BRI-PORT, or BRI-SET.<br />

a. If this Error Type is present for BRI-SET only, then release the<br />

station via the release station<br />

b. If this Error Type is present for BRI-PORT <strong>and</strong> BRI-SET, then<br />

release the port with release port location <strong>and</strong> run the<br />

<strong>test</strong> again.<br />

c. If the <strong>error</strong> is present for BRI-BD, BRI-PORT, <strong>and</strong> BRI-SET, then<br />

release the circuit pack with release port location <strong>and</strong><br />

run the <strong>test</strong> again.<br />

d. If the <strong>error</strong> is present for both BRI-BD <strong>and</strong> BRI-PORT, release<br />

the circuit pack with release board location <strong>and</strong> run the<br />

<strong>test</strong> again.<br />

e. If the <strong>error</strong> is present for BRI-SET only, release the circuit pack<br />

with release port location <strong>and</strong> run the <strong>test</strong> again.<br />

Note: When<br />

Note:<br />

you release the circuit pack, you release every port<br />

associated with it. If certain ports still need to be busied<br />

out, enter busyout port location to busy them out.<br />

2. Make sure the terminal is connected.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2 of 4<br />

Issue 5 May 2009 1415