Communication Manager Maintenance Object Repair Procedures<br />

2. If the ATM-EI circuit pack is absent or is present but in a PN that does not yet have PNC<br />

connectivity to it, use the change circuit-pack comm<strong>and</strong> to add circuit pack<br />

translation for the missing circuit pack.<br />

3. Enter add atm pnc n (connection number), <strong>and</strong> administer the circuit pack location <strong>and</strong><br />

ATM address.<br />

4. Enter change system-parameters duplication, <strong>and</strong> change the Enable<br />

Operation of PNC Duplication field to y.<br />

Removing ATM PNC Connections<br />

St<strong>and</strong>ard, Duplex or High Reliability<br />

Note: These<br />

Note:<br />

systems are not equipped with PNC duplication.<br />

1. Enter busyout atm pnc n (connection number).<br />

2. Enter remove atm pnc n (connection number).<br />

Critical Reliability<br />

1. Enter status pnc, <strong>and</strong> ensure that the A-PNC is active.<br />

If not, request a PNC interchange using the reset pnc interchange comm<strong>and</strong>.<br />

2. Enter busyout pnc-st<strong>and</strong>by.<br />

3. Enter change system-parameters duplication, <strong>and</strong> change the Enable<br />

Operation of PNC Duplication field to n.<br />

4. Enter busyout atm pnc n (PN’s number).<br />

5. Enter remove atm pnc n (PN’s number) to remove both ATM-EI boards, or enter<br />

change atm pnc to remove the B-side ATM-EI board.<br />

6. Enter change system-parameters duplication, <strong>and</strong> change the Enable<br />

Operation of PNC Duplication field to y.<br />

Changing Circuit Pack Location or ATM Address<br />

St<strong>and</strong>ard, Duplex or High Reliability<br />

Note: These<br />

Note:<br />

systems are not equipped with PNC duplication.<br />

1. Remove the ATM PNC connection. See Removing ATM PNC Connections.<br />

2. Add an ATM PNC connection. See Adding ATM PNC Connections.<br />