Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 310: Analog Line Station Lamp Update Test (#60) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

Analog Line Audits Test (#61)<br />

See NO BOARD for the recommended repair procedures.<br />

This <strong>test</strong> is a series of three audits. These audits will abort if attempted on an out-of-service<br />

station. The <strong>test</strong>s are as follows:<br />

● Switchhook Audit: This updates the server’s records according to the circuit packs’<br />

records.<br />

● Bad Scan Inquiry: An uplink message is sent containing a count generated due to certain<br />

events relating to the data link’s conditions. This indicates data-transmission problems<br />

between the circuit pack <strong>and</strong> the voice terminal.<br />

● EPF Inquiry: An uplink status message of the Electronic Power Feed is sent.<br />

This <strong>test</strong> is run on HYB-LINE (Hybrid Line) <strong>and</strong> MET-LINE (MET Line).<br />

Table 311: Analog Line Audits Test (#61) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 ABORT Internal system <strong>error</strong> during the switchhook audit.<br />

1. Make sure the station is not in an out-of-service state.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2 ABORT Internal system <strong>error</strong> during the bad scan audit.<br />

1. Make sure the station is not in an out-of-service state.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1172 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />