Error log entries <strong>and</strong> recommended actions<br />

Table 103: EPN-SNTY Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

0 (a) 0 Any None<br />

8801 (b) Any<br />

8803 (c) Any<br />

9901 (d) Any<br />

9902 (e) Any<br />

9903 (f) Any<br />

9904 (g) Any<br />

9905 (h) Any<br />

EPN-SNTY (PN Sanity Audit)<br />

Recommended<br />

Action<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error 8801: the PN is unable to send uplink control messages, <strong>and</strong> the control chel of the<br />

PN’s TDM bus is swapped as part of the recovery procedure.<br />

c. Error 8803: the PN is unable to send uplink control messages <strong>and</strong> the PN’s Tone-Clock is<br />

swapped as part of the recovery procedure.<br />

d. Error 9901: the PN is unable to send uplink control messages, but recovers after the<br />

control chels of the PN’s TDM bus are swapped.<br />

e. Error 9902: the PN is unable to send uplink control messages, but recovers after the PN’s<br />

active Tone-Clock is swapped.<br />

f. Error 9903: the PN is unable to send uplink control messages, but recovers after a PNC<br />

interchange has taken place.<br />

g. Error 9904: the PN is unable to send uplink control messages, but recovers after a PN<br />

WARM reset.<br />

h. Error 9905: the PN is unable to send uplink control messages, but recovers after a PN<br />

COLD reset.<br />