Table 311: Analog Line Audits Test (#61) 2 of 2<br />

Error<br />

Code<br />

Analog Line Audits Test (#61)<br />

3 ABORT Internal system <strong>error</strong> occurred during the EPF inquiry audit.<br />

1. Make sure the station is not in an out-of-service state.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000<br />

1004<br />

Test<br />

Result<br />

ABORT System resources required to run this <strong>test</strong> are not available.<br />

The port may be busy with a valid call.<br />

1. Enter display port location to determine the station<br />

extension number of the port.<br />

2. Enter status station to determine the service state of the port. If<br />

the port is in use, wait until it is idle before <strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1392 ABORT This port is a TTI port. The <strong>test</strong> does not run on TTI ports.<br />

1. Verify that the port is a TTI port using either display port (the<br />

port is a TTI port) or list config (shows a t for the port).<br />

2. If either list config or display port indicate that the port is<br />

not a TTI port, escalate the problem. If both comm<strong>and</strong>s indicate that<br />

the port is a TTI port, the abort is correct, <strong>and</strong> no action is<br />

necessary.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

PASS The Analog Line Audits <strong>test</strong> passed.<br />

1. Although this <strong>test</strong> never actually returns a FAIL result except for an<br />

Internal system <strong>error</strong>, it can enter Error Types 257 <strong>and</strong> 513 into the<br />

Error Log. To check for problems that don’t show up in the <strong>test</strong><br />

result, look for these Error Types in the Error Log.<br />

2. If these <strong>error</strong>s appear in the Error Log, or if user complaints still<br />

exist, investigate by using other circuit pack <strong>test</strong>s <strong>and</strong> by examining<br />

the station, wiring, <strong>and</strong> connections.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for the repair procedures.<br />