Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Stratum-3 Clock Alarm Query (#649)<br />

The Stratum-3 Clock Alarm Query Test queries the Stratum-3 clock for its alarm status <strong>and</strong><br />

reports the results of the query. The Stratum-3 clock provides the system with the following six<br />

alarm indications via the TN780 Tone-Clock circuit pack:<br />

● Reference A failed or CI card A failed.<br />

● Reference B failed or CI card B failed.<br />

● One power supply failed.<br />

● Every power supply failed.<br />

● One clock unit failed.<br />

● Every clock unit failed.<br />

! CAUTION:<br />

CAUTION: The removal of a card in the Stratum-3 clock may cause alarm(s) to be resolved<br />

<strong>and</strong> the query <strong>test</strong> to pass. However, the removed cards should still be replaced<br />

to restore the Stratum-3 clock to full service.<br />

This <strong>test</strong> runs on STRAT-3 (Stratum-3 Clock) <strong>and</strong> SYNC (Port Network Synchronization).<br />

Table 431: Stratum-3 Clock Alarm Query Test (#649) 1 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT The system could not allocate the necessary resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to up to 3 times.<br />

1005 ABORT This <strong>test</strong> aborts when it is run on a Stratum-4 system. Do not change<br />

synchronization to Stratum 3 without consulting the synchronization plan<br />

administrator for this switch.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1436 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />