Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 293: Port Diagnostic Test (#35) 6 of 6<br />

Error<br />

Code<br />

Test<br />

Result<br />

0 NO<br />

BOARD<br />

PASS ALARM-PT: The port’s battery feed chip is able to provide power to the<br />

external device alarm to detect contact closure.<br />

ANL-16-L, ANL-LINE, AN-LN-PT, RANL-STA: The port’s battery feed<br />

chip is able to provide power to the station equipment to detect on-/<br />

off-hook but may not be able to supply power for touch-tones.<br />

1. If touch-tones are not heard when buttons are pressed, replace<br />

the circuit pack or media module.<br />

2. Investigate user-reported troubles on this port by using other port<br />

<strong>test</strong>s, by examining station wiring, or by examining the station.<br />

DID-TRK: Current flow was detected for this port.<br />

1. Investigate user-reported troubles on this port by using other port<br />

<strong>test</strong>s <strong>and</strong> by examining connections to the port.<br />

2. If problems continue, refer the problem to the CO.<br />

MET-LINE: Current flow was properly detected for this port.<br />

1. Investigate user-reported troubles on this port by using other port<br />

<strong>test</strong>s <strong>and</strong> by examining connections to the port.<br />

Port Audit And Update Test (#36)<br />

The Port Audit <strong>and</strong> Update Test sends port level translation data from the switch processor to<br />

the circuit pack to verify that the port’s translation <strong>and</strong> current state are correct.<br />

When the ringer is in the off state, this <strong>test</strong> also turns off the station’s ringer to prevent constant<br />

ringing caused by defective hardware.<br />

For an analog line port which is administered as an external alarm, this <strong>test</strong> is limited to<br />

updating the software with the switchhook state.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● ADX16A-P (AUDIX Analog Line/Control Link)<br />

● ALARM-PT (Alarm Port)<br />

Description / Recommendation<br />

See NO BOARD for the repair procedures.<br />

1130 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />