TIE-TRK (Analog Tie Trunk)<br />

MO Name In Log Alarm Level Initial Comm<strong>and</strong> to Run 1<br />

TIE-TRK MAJ2 MIN<br />

TIE-TRK (Analog Tie Trunk)<br />

Full Name of MO<br />

1. If ATMS <strong>test</strong>ing is enabled, check the <strong>error</strong> log for ATMS <strong>error</strong>s 3840 <strong>and</strong> 3841. If the <strong>error</strong> log<br />

indicates that measurements exceeded acceptable thresholds, <strong>and</strong> no other trouble is found with<br />

<strong>test</strong> trunk, run the ATMS <strong>test</strong> call with <strong>test</strong> analog-<strong>test</strong>call port location full.<br />

2. A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by set options<br />

<strong>and</strong> that at least 75 percent of the trunks in this trunk group are alarmed.<br />

This alarm does not apply to TN497.<br />

<strong>test</strong> port location l Analog Tie Trunk<br />

WRN <strong>test</strong> port location<br />

Note:<br />

Note: Many trunk problems are caused by incorrect settings of parameters on the trunk<br />

group administration screen. Settings must be compatible with the local<br />

environment <strong>and</strong> with parameter settings on the far end. Refer to Administering<br />

<strong>Avaya</strong> Aura Communication Manager (03-300509). Refer to your <strong>Avaya</strong><br />

representative for the correct settings for administrable timers <strong>and</strong> other<br />

parameters on a country-by-country basis.<br />

The following circuit packs, including every suffix such as TN760D, support analog tie trunks:<br />

Table 263: Analog Tie Trunk Circuit Packs<br />

Code Trunk Type Signaling Leads<br />

TN760 4-wire E&M<br />

TN437 4-wire E&M<br />

TN439 2-wire A&B (2-way circuits only)<br />

TN458 4-wire E&M<br />

TN497 2-wire A&B<br />

TN2140 4-wire E&M<br />

Each tie trunk circuit pack occupies a port circuit pack slot <strong>and</strong> contains 4 port circuits. Each port<br />

circuit supports 1 analog tie trunk used to connect the switch to another PBX across 1- or 2-way<br />

dedicated circuits (see preceding list).<br />

Issue 5 May 2009 979