HYB-LINE (Hybrid Line)<br />

Notes:<br />

a. Error Type 1: The data link between the port <strong>and</strong> the terminal is not operational. (An<br />

off-board problem was detected by port circuit). Verify that the Hybrid set is connected <strong>and</strong><br />

that the Electronic Power Feed (EPF) <strong>test</strong> passes. If data transmission problems are<br />

experienced, check for defective wiring or a defective voice terminal, or move terminal<br />

closer to the switch (reduce the length of the wiring between the terminal <strong>and</strong> the switch). If<br />

the problem persists, replace the circuit pack. Once the problem has been resolved, the<br />

alarm will be retired after a predetermined delay.<br />

b. Error Type 15: a software audit <strong>error</strong> that does not indicate any hardware malfunction. Run<br />

the short <strong>test</strong> sequence <strong>and</strong> investigate any <strong>error</strong>s.<br />

c. Error Type 18: the port is busied out. Release the port with release port location.<br />

d. Error Type 130: the circuit pack has been removed or has been insane for more than<br />

11 minutes. To clear the <strong>error</strong>, reinsert or replace the circuit pack.<br />

e. Error Type 257: the EPF has been turned off due to an overcurrent condition at the voice<br />

terminal. Check for defective wiring or a damaged jack, <strong>and</strong> make sure the voice terminal is<br />

a Hybrid set. Once the problem has been resolved, the alarm will be retired after a<br />

predetermined delay.<br />

f. Error Type 513: the voice terminal has been disconnected or there is a problem in the<br />

wiring to the terminal. Make sure that the voice terminal is connected or check for defective<br />

wiring to the voice terminal.<br />

g. Error Type 769 <strong>and</strong> Error Type 1281: by themselves create Warning alarms. If both are<br />

present, a Minor alarm is logged.<br />

h. Error Type 1281 or 1537: the port has reported a problem with the data link to the voice<br />

terminal. Ignore this <strong>error</strong> if there are no complaints about the voice terminal. Otherwise,<br />

make sure the voice terminal is connected, check for defective wiring, check for a defective<br />

voice terminal, <strong>and</strong> decrease the length of the wiring between the voice terminal <strong>and</strong> the<br />

switch. If the problem persists, replace the circuit pack.<br />

i. The voice terminal went off-hook while in the disconnect state. Use status station to<br />

determine the state of the terminal. The off-hook should have moved the terminal to in<br />

service. No repair action is necessary.<br />

j. Error Type 2049: the link between the circuit pack <strong>and</strong> the voice terminal has been<br />

successfully reset. No repair action is necessary.<br />