The following terms are used in the <strong>error</strong> <strong>descriptions</strong>:<br />

Control Path The path between the two fiber endpoints that is necessary for the two<br />

endpoint circuit packs to communicate.<br />

Circuit Path The path between the two fiber endpoints that is necessary for circuit switched<br />

phone calls to work.<br />

Neighbor The circuit pack on the other end of the fiber.<br />

Out of Frame A circuit pack reports fiber out of frame if it cot detect valid data coming from<br />

the fiber.<br />

Packet Path The path between the two fiber endpoints that is necessary for<br />

packet-switched messages to be sent between the two fiber endpoints.<br />

LEDs for Circuit Packs on a Fiber Link<br />

The amber LEDs on the three types of boards, SNI (TN573), EI (TN570), <strong>and</strong> DS1 Converter<br />

(TN574 or TN1654), that may be a part of the fiber link can help in diagnosing problems with the<br />

fiber link. The amber LED states are as follows. The flashing LED patterns take precedence<br />

over the active or st<strong>and</strong>by LED patterns.<br />

If both endpoints of a fiber link (EI <strong>and</strong>/or SNI) are flashing with a fiber out of frame pattern, a<br />

fast amber LED pattern (0.1 second on <strong>and</strong> 0.1 second off), check the lightwave transceivers (if<br />

present). Both lightwave transceivers on the fiber link must be of the same type. The 9823a<br />

shortwave transceiver <strong>and</strong> the 9823b longwave transceiver must never be combined on the<br />

same fiber link because a fiber out-of-frame condition will exist. The 9823a lightwave<br />

transceiver should be used for distances up to 4900 feet <strong>and</strong> the 9823b lightwave transceiver<br />

should be used for distances up to 25,000 feet.<br />

Table 115: SNI Amber LED Flashing Codes<br />

Condition LED on LED off<br />

Fiber out of Frame 0.1 second 0.1 second<br />

In Frame, No Neighbor1 0.5 second 0.5 second<br />

SNI active Solid on Never off<br />

SNI st<strong>and</strong>by Never on Solid off<br />

1. The fiber is in frame, but no communication exists to<br />

the neighbor<br />

462 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers