Table 358: Digital Looparound Test (#171) 4 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Data Module Internal Looparound Test (#175)<br />

Data Module Internal Looparound Test (#175)<br />

2500 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 FAIL No response received within the time allowed.<br />

1. If the <strong>test</strong> fails again, replace the Data Line circuit pack.<br />

FAIL The data received did not match the data sent. This indicates a fault<br />

somewhere in the transmit/receive path to the TDM Bus, which will<br />

probably result in data corruption over this port. This <strong>test</strong> may fail if the<br />

Maintenance/Test digital port used by the <strong>test</strong> is not functioning properly.<br />

1. Resolve any M/T-DIG (Maintenance/Test Digital Port) <strong>error</strong>s.<br />

2. Repeat Test #171.<br />

3. If the <strong>test</strong> fails again, replace the data line circuit pack.<br />

PASS The port can correctly transmit/receive data. Investigate user-reported<br />

troubles on this port using other port <strong>test</strong>s by examining the ADU, external<br />

wiring, <strong>and</strong> customer equipment.<br />

4 of 4<br />

This <strong>test</strong> verifies that a data message can be sent from the switch, through the building wiring,<br />

through an internal looparound path in the data module, <strong>and</strong> back to the switch. This path is<br />

illustrated below.<br />

For this <strong>test</strong> to run, the Remote Looparound Test field on the Data Module administration<br />

screen must be set to y, indicating that the data module endpoint supports the <strong>test</strong>.<br />

This <strong>test</strong> runs on PDMODULE (Processor Data Module) <strong>and</strong> TDMODULE (Trunk Data Module).<br />