ADX16D-P (16-Port AUDIX Digital Port)<br />

CAUTION: Never<br />

MO Name in Log Alarm<br />

Level<br />

ADX16D-P MIN<br />

WRN<br />

ADX16D-P (16-Port AUDIX Digital Port)<br />

! CAUTION:<br />

do any of the following without first shutting down AUDIX. Follow the<br />

instructions on the TN566/TN2169 faceplate:<br />

● Remove EMBEDDED AUDIX circuit packs<br />

Initial Comm<strong>and</strong> to Run Full Name of MO<br />

<strong>test</strong> port location l AUDIX Digital port<br />

● Cycle power to a carrier containing EMBEDDED AUDIX circuit packs<br />

● Remove power to a carrier or cabinet containing EMBEDDED AUDIX circuit pack<br />

The ADX16D-P MO represents a port on a TN566/TN2169 EMBEDDED AUDIX circuit pack<br />

operating in digital-port (DP) mode. The maintenance strategy for ports on the TN566 operating<br />

in control-link mode is described in ADX16A-P (AUDIX Analog Line/Control Link).<br />

The <strong>test</strong>s apply only to switch-side maintenance that <strong>test</strong>s a circuit pack’s components related<br />

to the TDM-bus interface. The AUDIX system has an extensive maintenance strategy that is<br />

described in DEFINITY® AUDIX Maintenance, 585-300-110.<br />

AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction board (MFB) <strong>and</strong><br />

the TN2169 Alarm board (ALB). The 2 boards occupy 5 slots, but the system sees only 1 slot as<br />

functional. The other 4 slots are seen by the switch as “AUDIX-reserved” slots (or ADX16-RES/<br />

ADX16D-RS).<br />

In 16-port DP mode, the TN566 pack supports up to 16 voice ports, each with a primary <strong>and</strong> a<br />

secondary information chel. Ports are administered in increments of two. When a call to a<br />

station with an AUDIX login is not answered, AUDIX answers the call using one of the available<br />

voice ports.<br />

Unlike other AUDIX systems, EMBEDDED AUDIX is not an adjunct.<br />