Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 417: Electronic Power Feed Inquiry Test (#622) 2 of 2<br />

Error<br />

Code<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. If the <strong>test</strong> aborts repeatedly up to five times, reset the circuit pack<br />

<strong>and</strong> rerun the <strong>test</strong>.<br />

2. If the <strong>test</strong> aborts again, replace the circuit pack.<br />

2012<br />

2100<br />

Test<br />

Result<br />

Description / Recommendation<br />

CRC Error Counter Test (#623)<br />

Internal system <strong>error</strong>.<br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to abort, escalate the problem.<br />

1 FAIL The BRI-LINE circuit pack reports that it has detected an overcurrent<br />

condition <strong>and</strong> has turned off the EPF.<br />

1. As necessary, check <strong>and</strong> repair the wiring between the circuit pack<br />

<strong>and</strong> the endpoint or adjunct. Check the endpoints <strong>and</strong> replace one<br />

or both sets if the sets are drawing too much current. Enter <strong>test</strong><br />

port location <strong>and</strong> review the results of the EPF Inquiry <strong>test</strong> to<br />

verify the repair. If this <strong>test</strong> is still failing, proceed to step 2.<br />

2. Enter <strong>test</strong> port location, <strong>and</strong> review the results of the Level 1<br />

Status Inquiry <strong>test</strong>. If this <strong>test</strong> is also failing, then follow the repair<br />

procedure for the Level 1 Status Inquiry <strong>test</strong>. Otherwise, escalate<br />

this problem to the next tier.<br />

PASS The Electronic Power Feed Inquiry <strong>test</strong> reports that the EPF is on.<br />

This <strong>test</strong> reads the port’s CRC <strong>error</strong> counters that are maintained on the circuit pack. The Cyclic<br />

Redundancy Check (CRC) is a means of <strong>error</strong> detection to determine the integrity of data frame<br />

contents. The CRC <strong>error</strong> counter is incremented by the circuit pack when it detects a CRC <strong>error</strong>.<br />

The <strong>test</strong> passes if the value of the counter is 0, meaning the <strong>error</strong> is cleared. If the counter is<br />

non-zero, the <strong>test</strong> fails <strong>and</strong> the value of the counter is displayed in the Error Code field.<br />

This <strong>test</strong> runs on ASAI-PT (ASAI Port), BRI-PORT (ISDN-BRI Port), <strong>and</strong> TBRI-PT (ISDN<br />

Trunk-Side BRI Port).<br />

1408 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 2