S8700-series Fiber-PNC<br />

Stratum-3 Synchronization<br />

Since the clock module on the TN2312 does not support synchronization with an external<br />

Stratum-3 clocking device, you may provide Stratum-3 clocking for a S8700 Server system by<br />

using the TN780 Tone-Clock circuit pack in a non IPSI connected port network. To bring in the<br />

external Stratum-3 clocking signals into the TN780, a processor carrier is needed. This new PN<br />

control carrier will replace the processor carrier in the old PPN converted to PN 1. The<br />

Stratum-3 clocking must come into Port Network #1 because the S8700 Fiber-PNC software<br />

has the Stratum-3 clocking hard-coded to this port network.<br />

Stratum-4 Synchronization<br />

The system can be configured with primary <strong>and</strong> secondary synchronization references (DS1 or<br />

UDS1 Interface circuit packs) when using Stratum-4 synchronization. If this is the master<br />

synchronization source for the network, then its local oscillator is used <strong>and</strong> no DS1s are used as<br />

references.<br />

If this system is a slave in the network, a primary reference must be used as the synchronization<br />

reference <strong>and</strong> a secondary reference is optional:<br />

● If the primary synchronization reference is not providing a valid timing signal, the system<br />

automatically switches to the secondary synchronization reference.<br />

● If the primary synchronization reference is invalid <strong>and</strong> secondary reference does not<br />

provide a valid timing signal or is not administered as a synchronization reference, an<br />

IPSI’s Tone-Clock circuit or a Tone-Clock circuit pack provides the PN’s timing source.<br />

● If the system is using the local oscillator as the timing source (both the primary <strong>and</strong><br />

secondary references are providing invalid timing signals), should either the primary or<br />

secondary reference becomes valid again, the system (PN for S8700 Server systems)<br />

switches back to the primary or secondary source.<br />

● When both the primary <strong>and</strong> secondary source become valid, the system switches to the<br />

primary source, since the primary source is always preferred over the secondary source<br />

when both sources are equally healthy.<br />

Synchronization Troubleshooting<br />

For Stratum-4 operation, major <strong>and</strong> minor alarms indicate that there is a problem with the<br />

system synchronization references. These alarms will be resolved when the alarmed<br />

synchronization reference is restored.<br />

896 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers