Table 418: CRC Error Counter Test (#623)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Layer 1 Transmission Error Counter Test (#624)<br />

2000 ABORT Response was not received from the circuit pack within the allowed time.<br />

1. If the <strong>test</strong> aborts repeatedly up to 5 times, reset the circuit pack <strong>and</strong><br />

rerun the <strong>test</strong>.<br />

2. If the <strong>test</strong> aborts again, replace the circuit pack.<br />

2012<br />

2100<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

Any FAIL The circuit pack is detecting CRC <strong>error</strong>s. The Error Code field contains<br />

the value of the counter. This <strong>error</strong> occurs when a frame with a bad CRC<br />

is received over the D-Chel by the circuit pack.<br />

The problem is most likely due to a problem with the wiring to the set or<br />

adjunct, interference on the wiring caused by a noise source such as an<br />

electrical motor or generator, or no termination (open circuit). It usually<br />

does not indicate a problem with the circuit pack.<br />

PASS The <strong>error</strong> counter was cleared successfully.<br />

Layer 1 Transmission Error Counter Test (#624)<br />

This <strong>test</strong> reads <strong>and</strong> clears the port’s Layer 1 Transmission <strong>error</strong> counter maintained on the ASAI<br />

or BRI-LINE circuit pack. This counter is incremented by the circuit pack when it detects a Layer<br />

1 transmission problem. The <strong>test</strong> passes if the value of the counter is 0 (that is, the <strong>error</strong> is<br />

cleared). If the counter is not zero, the <strong>test</strong> fails, <strong>and</strong> the value of the counter is displayed in the<br />

Error Code field.<br />

This <strong>error</strong> is most likely due to a problem with the wiring or the endpoint or adjunct. Verify that<br />

the wiring meets the configuration rules defined in DEFINITY® Communications System<br />

Generic 1 <strong>and</strong> Generic 3i Wiring, 555-204-111. It does not indicate a problem with the circuit<br />