Note: For<br />

Note: For<br />

Note:<br />

the I-CSU/T1 sync splitter only, the ELB <strong>test</strong> is also executed as part of<br />

<strong>test</strong> ds1-loop location ds1/csu-loopback-<strong>test</strong>s. Try to clear the<br />

alarm using busyout board location, <strong>test</strong> ds1-loop location ds1/<br />

csu-loopback-<strong>test</strong>s, <strong>and</strong> release board location. If the ELB <strong>test</strong><br />

continues to fail, then either the UDS1 board, the CSU module, or the I/O cable<br />

between the backplane <strong>and</strong> the CSU module, or any combination thereof, failed.<br />

Try to isolate where the failure is occurring by re-executing the <strong>test</strong> <strong>and</strong> by<br />

replacing one piece of hardware at a time.<br />

p. Error Type 1312: RLB failure. This <strong>error</strong> occurs when the Repeater Loopback (RLB) <strong>test</strong><br />

fails for the Integrated CSU (I-CSU) module/T1 sync splitter or for the 402A or 403A E1<br />

synchronization splitter. This <strong>test</strong> is executed by the I-CSU/E1SS during I-CSU/E1SS<br />

power-up/reset (i.e., DS1 board physically inserted <strong>and</strong> 120A1 CSU module or the 401A T1<br />

sync splitter, or the 402A or 403A E1SS is already installed) or when the 120A1 CSU<br />

module or the 401A T1 sync splitter, or the 402A or 403A E1SS is plugged on to an already<br />

initialized DS1 board.<br />

Note:<br />

the I-CSU/T1 sync splitter only, the RLB <strong>test</strong> is also executed as part of the<br />

<strong>test</strong> ds1-loop location ds1/csu-loopback-<strong>test</strong>s. Try to clear the<br />

alarm using busyout board location, <strong>test</strong> ds1-loop location ds1/<br />

csu-loopback-<strong>test</strong>s, <strong>and</strong> release board location. If the RLB <strong>test</strong><br />

continues to fail, replace the CSU module.<br />

q. Error Type 1313: CPE Loopback Jack deactivation <strong>error</strong>. This <strong>error</strong> occurs when the UDS1<br />

circuit pack could not deactivate a CPE Loopback Jack on power-up/reset or upon software<br />

request.<br />

Try to clear the alarm using busyout board location, <strong>test</strong> ds1-loop location<br />

end-loopback/span-<strong>test</strong>, <strong>and</strong> release board location. If the attempt to<br />

deactivate the CPE Loopback Jack continues to fail, other steps must be taken to<br />

deactivate the loopback.<br />

r. Error Type 1314: far CSU Loopback deactivation <strong>error</strong>. This <strong>error</strong> occurs when the UDS1<br />

circuit pack could not deactivate a far-end CSU loopback on power-up/reset or upon<br />

software request.<br />

Try to clear the alarm using busyout board location, <strong>test</strong> ds1-loop location<br />

end-loopback/span-<strong>test</strong>, <strong>and</strong> release board location. If the attempt to<br />

deactivate the Far CSU loopback continues to fail, escalate the problem.<br />

s. Error Types 1400, 1401: echo cancellation <strong>error</strong>s are logged when:<br />

● Error 1400: echo canceller function failed. The Echo Canceller Function <strong>test</strong>, which is<br />

executed by firmware, failed.<br />

● Error 1401: echo canceller memory failed. The Echo Canceller Memory <strong>test</strong>, which is<br />

executed by firmware, failed.<br />

1036 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers