Table 295: Tone Generator Transmission Test (#40) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Tone Generator Transmission Test (#40)<br />

2000 ABORT Response to the <strong>test</strong> was not received within the time allowed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT System resources required for this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 (a) FAIL DTMF generation failed for the active tone generator.<br />

105 (a) FAIL Generation of 440-Hz failed.<br />

109 (a) FAIL Generation of 2225-Hz failed.<br />

110 (b) FAIL Generation of 404-Hz level invalid.<br />

111 (b) FAIL Generation of 1004-Hz low level invalid.<br />

112 (b) FAIL Generation of 1004-Hz high level invalid.<br />

113 (b) FAIL Generation of 2804-Hz level invalid.<br />

115 (b, c) FAIL Generation of digital count sequence invalid.<br />

120 (a) FAIL Generation of quiet tone failed.<br />

1044 (a) FAIL DTMF generation failed to generate Digit 1 for the st<strong>and</strong>by tone<br />

generator.<br />

1045 (a) FAIL DTMF generation failed to generate Digit 5 for the st<strong>and</strong>by tone<br />

generator.<br />

1046 (a) FAIL DTMF generation failed to generate Digit 9 for the st<strong>and</strong>by tone<br />

generator.<br />

1047 (a) FAIL DTMF generation failed to generate Digit D for the st<strong>and</strong>by tone<br />

generator.<br />

PASS The tone generation facility is able to generate <strong>and</strong> transmit all the<br />

tones.<br />

2 of 2<br />

Notes:<br />

Except in EPNs containing more than one IPSI or Tone-Clock circuit pack, replacing an IPSI or<br />

Tone-Clock circuit pack is a service disrupting procedure. The <strong>test</strong> should be run several times<br />

with more than one failure before the replacement policy specified in the following notes is<br />

executed. Use the procedure described in Replacing the IPSI or Tone-Clock Circuit Pack.<br />