Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Control Chel Test (#296)<br />

The Control Chel Test <strong>test</strong>s the integrity of the Control Chel bus by ensuring that communication<br />

through the TDM bus is operational. The <strong>test</strong> attempts to query a Tone-Clock or Tone Detector<br />

circuit pack which is required in each port network for proper operation. If a reply from the<br />

queried circuit pack is received, the TDM bus is considered operational <strong>and</strong> the <strong>test</strong> passes. If<br />

no reply is received, the TDM Bus is not operational <strong>and</strong> the <strong>test</strong> fails.<br />

This <strong>test</strong> runs on TDM-BUS (TDM Bus).<br />

Table 385: Control Chel Test (#296)<br />

Error<br />

Code<br />

Any<br />

other<br />

than<br />

1005<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1005 ABORT This <strong>test</strong> is valid only on the control chel bus. It aborts when run on the<br />

non-control chel bus. This is a valid response. Enter<br />

status port-network to verify which bus is the control chel bus.<br />

None FAIL Communication through the Control Chel is not working. The problem is<br />

not necessarily the TDM bus itself.<br />

1. Display the hardware <strong>error</strong> <strong>and</strong> alarm log for the Tone-Clock circuit<br />

<strong>and</strong> for the Tone Detector circuit in the port network where the faulted<br />

TDM bus resides. See the following to resolve <strong>error</strong>s:<br />

TONE-BD (Tone-Clock Circuit Pack)<br />

TONE-PT (Tone Generator)<br />

GPTD-PT (General-Purpose Tone Detector Port)<br />

DTMR-PT (Dual-Tone Multifrequency Receiver Port).<br />

2. Resolve any <strong>error</strong>s <strong>and</strong> alarms for the Tone-Clock <strong>and</strong> Tone Detector<br />

circuits.<br />

3. Display the hardware <strong>error</strong> <strong>and</strong> alarm log <strong>and</strong> look for <strong>error</strong>s <strong>and</strong><br />

alarms for the active Expansion Interface circuit pack. See EXP-INTF<br />

(Expansion Interface Circuit Pack) <strong>and</strong> resolve its <strong>error</strong>s.<br />

4. Enter <strong>test</strong> tdm P<br />

5. If the <strong>test</strong> still fails, see TDM-Bus Fault Detection <strong>and</strong> Isolation.<br />

PASS Communication through the control chel bus is operational.<br />

1344 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers