Error log entries <strong>and</strong> recommended actions<br />

Table 31: ATM-DCH Error Log entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

ATM-DCH (ATM D-Chel Port)<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 18: D-Chel busied out. No calls possible over this D-Chel.<br />

c. Error Type 130: circuit pack removed or has been insane for more than 11 minutes. To<br />

clear the <strong>error</strong>, reinsert or replace the circuit pack.<br />

d. Error Type 1793: ATM Trunk circuit pack failed the Signaling Link Board check (#643).<br />

Resolve any ATM-TRK (Circuit Emulation Service Circuit Pack) <strong>error</strong>s in the Error Log.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> port location<br />

18 (b) 0 busyout port<br />

location<br />

WRN OFF release port location<br />

130 (c) WRN ON <strong>test</strong> port location<br />

1793 (d) Signaling Link Board<br />

check (#643)<br />

The comm<strong>and</strong> to <strong>test</strong> the ATM-DCH MO is <strong>test</strong> port location, where location is port<br />

number 9-32.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

<strong>test</strong> board location l<br />

D/ND<br />

Signaling Link Board Check (#643) X X Nondestructive<br />