19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Table 471: SNI Fiber Out of Frame Query Test (#989) 7 of 8<br />

Error<br />

Code<br />

243<br />

244<br />

Test<br />

Result<br />

Description / Recommendation<br />

SNI Fiber Out of Frame Query Test (#989)<br />

FAIL The SNI circuit pack (Endpoint 2 of the fiber link) has a loss-of-signal<br />

condition, but no fiber out-of-frame condition.<br />

Error Code 243: a lightwave transceiver is connected to the SNI circuit<br />

pack.<br />

Error Code 244: no lightwave transceiver is connected to the SNI circuit<br />

pack.<br />

1. Check that the connected circuit pack is physically installed. The<br />

connected circuit pack is the other endpoint of the fiber-link if no DS1<br />

converter complex is administered. Check using list<br />

fiber-link. Otherwise, if a DS1 converter complex is<br />

administered, the connected circuit pack is the DS1 converter circuit<br />

pack connected to the SNI circuit pack.<br />

2. Perform the Fiber link fault isolation in Chapter 4: General<br />

troubleshooting in Maintenance Procedures for <strong>Avaya</strong> Aura<br />

Communication Manager, Media Gateways <strong>and</strong> Servers<br />

(03-300432) in Chapter 5.<br />

3. Replace this SNI circuit pack.<br />

4. Replace the connected circuit pack.<br />

7 of 8<br />

Issue 5 May 2009 1555