CONFIG (System Configuration)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

CONFIG none none System Configuration<br />

The System Configuration MO oversees logical insertion <strong>and</strong> removal of circuit packs in the<br />

system. When the system detects that a circuit pack is present in a port slot, it queries the circuit<br />

pack to determine the type <strong>and</strong> vintage of the circuit pack. The system also detects when a<br />

circuit pack has been removed from a port slot.<br />

There are no alarms or <strong>test</strong>s for System Configuration, but three types of <strong>error</strong>s are logged to<br />

the <strong>error</strong> log.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 77: CONFIG Error Log Entries<br />

Error Type Aux Data Associated<br />

Test<br />

0 (a) 0<br />

1–119 (b) 0–63<br />

Alarm<br />

Level<br />

257 (c) MAJ<br />

1001–1119 (d) 0–63<br />

On/Off<br />

Board<br />

Notes:<br />

a. Error Type 0:An attempt was made by the system to raise an alarm against CONFIG<br />

without first logging a CONFIG <strong>error</strong>.<br />

b. Error Types 1-119: a port circuit pack in the system did not respond to a circuit pack type<br />

inquiry. Follow the procedures outlined in (d) to determine whether there is an <strong>error</strong>.<br />

c. Error Type 257: less than 25% of a trunk group is available.<br />

d. Error Types 1001 - 1119: a port circuit pack in the system did not respond to a vintage<br />

inquiry. A port circuit pack may be physically inserted in a port slot, but the system may not<br />

recognize its existence. The Aux Data value specifies the circuit pack’s internal port<br />

network number. To convert the Aux Data value to the physical port network number, add<br />

290 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />