DIOD-TRK (DIOD Trunk)<br />

DIOD-TRK (DIOD Trunk)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

DIOD-TRK MAJ1 MIN<br />

WRN<br />

Many trunk problems are caused by incorrect settings of parameters on the trunk group<br />

administration screen. Settings must be compatible with the local environment <strong>and</strong> with<br />

parameter settings on the far end. Refer to the Administering <strong>Avaya</strong> Aura Communication<br />

Manager (03-300509), for information about how to administer trunks. Refer to your <strong>Avaya</strong><br />

representative for the correct settings for administrable timers <strong>and</strong> other parameters on a<br />

country-by-country basis.<br />

Direct inward <strong>and</strong> outward dial (DIOD) trunks are 2-wire analog lines to the CO which support<br />

the following services:<br />

● Both incoming <strong>and</strong> outgoing CO calls<br />

● DID trunk<br />

● DID trunk <strong>and</strong> 1-way outgoing DIOD<br />

TN429 DIOD trunk circuit packs <strong>and</strong> MM711 Analog Media Modules provide eight ports for<br />

loop-start CO trunks <strong>and</strong> serve as an interface between the 2-wire analog CO line <strong>and</strong> the<br />

4-wire TDM bus on the switch.<br />

Not all <strong>test</strong>s that run on circuit packs are applicable to media modules. These <strong>test</strong>s will abort<br />

with <strong>error</strong> code 1412. This <strong>error</strong> can be ignored.<br />

Loop Start Operation<br />

Idle State: Tip = ground, Ring = CO Battery<br />

Outgoing Call<br />

<strong>test</strong> port location DIOD Trunk<br />

1. A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by set<br />

options <strong>and</strong> that at least 75 percent of the trunks in this trunk group are alarmed.<br />

1. PBX Off-Hook (Seize Message): Closes the Tip-Ring Loop<br />

2. CO Response: DC loop current + Dial tone<br />

3. PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current<br />

4. CO Response: CO goes to idle state (see Note)<br />