Table 314: Tie Trunk EPF Test (#74) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Tie Trunk EPF Test (#74)<br />

1014 ABORT The circuit pack has not been inserted into the system.<br />

1. Enter list configuration board to verify that the circuit pack<br />

is inserted in the carrier.<br />

2. If the board is not inserted, make sure the circuit pack is inserted in<br />

the carrier <strong>and</strong> fully seated.<br />

1040 ABORT This <strong>test</strong> is not performed for trunk ports administered as access<br />

endpoints.<br />

1. Verify this port is an access endpoint by using display port.<br />

2. If the port has been administered as an access endpoint, this <strong>test</strong><br />

should abort <strong>and</strong> no action is necessary.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run the <strong>test</strong>. This<br />

could be due to a failure to seize the port.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 FAIL The E lead <strong>test</strong> failed due to an on-board port problem.<br />

1. Replace the circuit pack.<br />

2 FAIL The M lead <strong>test</strong> failed. The EPF has experienced an overcurrent<br />

condition, perhaps due to the external M lead.<br />

1. To make sure the problem is on-board, disconnect the facility from<br />

the pack <strong>and</strong> retry the <strong>test</strong>.<br />

2. If the <strong>test</strong> fails, replace the circuit pack. Otherwise, check the<br />

external wiring toward the far-end PBX.<br />

PASS Tie Trunk EPF <strong>test</strong> is successful. This port is functioning properly.<br />

1. If users are reporting troubles, examine loop connections to the port.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for the recommended repair procedures.<br />

2 of 2<br />

Issue 5 May 2009 1179