If Then<br />

There are no packet bus<br />

alarms<br />

ATM-TRK (Circuit Emulation Service Circuit Pack)<br />

r. Error Type 3585: Major board alarm; failure of critical components involved in the operation<br />

of the circuit pack. The circuit pack has failed, <strong>and</strong> the switch can no longer recognize it.<br />

1. Run <strong>test</strong> board location long.<br />

Run the following comm<strong>and</strong> sequence:<br />

1.busyout board location<br />

2.reset board location<br />

3.<strong>test</strong> board location long<br />

4.release board location<br />

The problem persists Replace the ATM-TRK circuit pack.<br />

Aux<br />

Data<br />

Description<br />

1 ATM framer chip failure<br />

2 NCE failed<br />

4 TDM PLD failed<br />

5 Every DSP on the circuit pack has failed.<br />

6 RNP (Receive Network Processor) failed<br />

7 TNP (Transmit Network Processor) failed<br />

8 MEMORY read/write failure<br />

9 DUART failure<br />

If Then<br />

Test #1259 fails with Error Code XXYY<br />

<strong>and</strong> XX is an AUX value in the<br />

preceding table<br />

The system does not recognize the<br />

circuit pack<br />

2 of 2<br />

Replace the ATM-TRK circuit pack.<br />

Replace the ATM-TRK circuit pack.<br />

s. Error Type 3841: the ATM-TRK circuit pack received an unrecognized message from the<br />

switch <strong>and</strong> responded with an inconsistent down-link <strong>error</strong> message.<br />

1. Do nothing. This <strong>error</strong> does not affect service.<br />