Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

When the BLB <strong>test</strong> is initiated, maintenance software sends a message to the DS1 Interface<br />

circuit pack. The board sets up the BLB loopback, transmits a <strong>test</strong> pattern, <strong>and</strong> verifies that the<br />

pattern is received unaltered through the loopback. If the transmitted <strong>and</strong> received patterns are<br />

different, the <strong>test</strong> fails.<br />

When the <strong>test</strong> is complete, enter release board to restore all trunks or ports on the DS1<br />

Interface circuit pack to the in-service state.<br />

This <strong>test</strong> is run on the following maintenance objects:<br />

● DS1-BD (DS1 Interface Circuit Pack)<br />

● MG-DS1 (DS1 Interface Media Module)<br />

● UDS1-BD (UDS1 Interface Circuit Pack)<br />

Table 482: DS1 Board Loopback Test (#1209) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry <strong>test</strong> ds1-loop location ds1/csu-loopback-<strong>test</strong>s<br />

at 1-minute intervals up to 5 times.<br />

1005 ABORT The DS1 Board Loopback <strong>test</strong> cot be executed in the current configuration.<br />

To run this <strong>test</strong>, the DS1 must be administered for 24-chel operation. The<br />

Bit Rate field on the DS1 circuit pack administration screen must be set<br />

to “1.544” for 24-chel operation.<br />

1015 ABORT Ports on the DS1 Interface circuit pack have not been busied out.<br />

1. Enter busyout board location to put all trunks or ports of the<br />

DS1 Interface circuit pack into the out-of-service state.<br />

2. Retry the comm<strong>and</strong>.<br />

1039 ABORT The DS1 Interface circuit pack is providing timing for the system. Executing<br />

this <strong>test</strong> could cause major system disruption.<br />

If the DS1 Interface circuit pack needs to be <strong>test</strong>ed, set the<br />

synchronization reference to another DS1 Interface circuit pack or to the<br />

IPSI or Tone-Clock circuit pack using the following comm<strong>and</strong> sequence:<br />

1. disable synchronization-switch<br />

2. set synchronization location<br />

3. enable synchronization-switch<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore.<br />

1578 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />