GPTD-PT (General-Purpose Tone Detector Port)<br />

MO Name in<br />

Log<br />

Alarm<br />

Level<br />

GPTD-PT MAJ<br />

MIN<br />

GPTD-PT (General-Purpose Tone Detector Port)<br />

Initial Comm<strong>and</strong> to Run Full Name of MO<br />

<strong>test</strong> port location General-Purpose Tone Detector Port<br />

WRN release port location<br />

The GPTD (General-Purpose Tone Detector) ports are also known as CPTRs (Call-Progress<br />

Tone Receivers).<br />

Tests on the GPTD port perform level measurements of <strong>test</strong> tones <strong>and</strong> detect call-progress<br />

tones. Examples of call-progress tones are dial tone, ring back, busy, alert, confirmation, <strong>and</strong><br />

recall dial.<br />

For Tone Detector circuit pack <strong>error</strong>s (DETR-BD), see XXX-BD (Common Port Circuit Pack/<br />

Media Module).<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 133: GPTD-PT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (b) 0 Any Any Any <strong>test</strong> port location<br />

1 17664 Tone Detector Audit/<br />

Update (#43)<br />

18 0 busyout port<br />

location<br />

MAJ<br />

MIN(a)<br />

ON <strong>test</strong> port location r 2<br />

WRN ON release port location<br />

130 (e) WRN ON <strong>test</strong> port location r 2<br />

257 (c) 17666 Tone Detector Audit/<br />

Update (#43)<br />

513 (d) Any Tone Detection<br />

Verification (#42)<br />

MAJ<br />

MIN (a)<br />

MAJ<br />

MIN (a)<br />

ON <strong>test</strong> port location r 3<br />

ON <strong>test</strong> port location r 3<br />

Notes:<br />

a. A Major or a Minor alarm may be logged with this <strong>error</strong>. A Major alarm is raised when the<br />

total number of GPTD ports currently in service is less than or equal to 1/2 of the threshold<br />