Table 333: OLS Recycle Test (#126) 2 of 2<br />

Error<br />

Code<br />

2029 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2319 ABORT PNN out of range - internal <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2320 ABORT Invalid carrier - internal <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2500 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

255 FAIL Did not receive uplink alarm from the carrier.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 (E)<br />

2 (D)<br />

4 (A)<br />

8 (B)<br />

16 (C)<br />

Test<br />

Result<br />

Description / Recommendation<br />

OLS Recycle Test (#126)<br />

FAIL There is a problem with one or both OLSs on the cycled carrier.<br />

1. Since the OLS Recycle <strong>test</strong> failed, both OLSs in the cycled carrier<br />

should have been powered off by the system software. Both OLSs<br />

should have a red status LED turned on instead of amber. Since<br />

the OLS Query <strong>test</strong> is a subset of the OLS Recycle <strong>test</strong>, the OLS<br />

Query <strong>test</strong> (#127) should also fail. Run the OLS Query <strong>test</strong> by<br />

using<br />

<strong>test</strong> environment location where location is the<br />

appropriate cabinet number.<br />

2. If Test #127 fails, follow the repair procedures for the OLS/Power<br />

Unit Query Test (#127).<br />

PASS Both OLSs in the recycled carrier were found to be healthy by a PN’s<br />

Maintenance circuit pack after the OLSs were powered down <strong>and</strong> back<br />

up. If the status LEDs on both OLSs are not showing amber, then the<br />

MAINT (Maintenance) circuit pack may have incorrectly reported the state<br />

of the OLSs. Resolve any alarms on these MOs.<br />

2 of 2<br />

Issue 5 May 2009 1225