Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 527: Signaling Group Ping Test (#1387) 3 of 3<br />

Error<br />

Code<br />

2802 ABORT Different IP address pinged than software had allocated for the <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

7<br />

89<br />

1007<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL PING to the destination failed through this port because the destination<br />

was down.<br />

1. Verify that at least one destination reachable through this port is<br />

“up”. Once verified, enter <strong>test</strong> signaling-group grp# to verify<br />

that the Signaling Group Ping <strong>test</strong> (#1387) passes.<br />

Any PASS PING through this port was successful.<br />

MedPro Status Test (#1392)<br />

This <strong>test</strong> determines if at least one media processor port is in service <strong>and</strong> serves the same<br />

region as the C-LAN that the signaling group uses. If at least port one exists <strong>and</strong> is in service,<br />

the <strong>test</strong> passes. Otherwise, the <strong>test</strong> fails.<br />

This <strong>test</strong> runs on H323-SGR (H.323 Signaling Group) <strong>and</strong> SIP-SGRP (SIP Signaling Group).<br />

Table 528: MedPro Status Test (#1392) 1 of 2<br />

Error<br />

Code<br />

None<br />

2012<br />

2100<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong>.<br />

Internal system <strong>error</strong>.<br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times<br />

2808 ABORT This <strong>test</strong> is not applicable when the SBS field on the H.323 signaling<br />

group form is set to y.<br />