Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

TDM Bus Clock Circuit Status Inquiry Test (#148)<br />

This <strong>test</strong> checks the sanity of the TDM Bus Clock circuitry.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● TDM-CLK (TDM Bus Clock)<br />

● TONE-BD (Tone-Clock Circuit Pack)<br />

● TONE-PT (Tone Generator)<br />

Table 346: TDM Bus Clock Circuit Status Inquiry Test (#148) 1 of 3<br />

Error<br />

Code<br />

None<br />

1001<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT The system could not allocate the necessary resources for the <strong>test</strong>.<br />

1. Wait 1-minute, <strong>and</strong> retry the <strong>test</strong>.<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT System resources required to run this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 FAIL The Tone-Clock circuit framing verification firmware found an <strong>error</strong> in<br />

the clock synchronization signal coming into this port network.<br />

1. If the Tone-Clock circuit reporting the problem is a master clock,<br />

then the system synchronization reference is providing a bad<br />

timing source. See SYNC (Port Network Synchronization) or<br />

Notes: to change the system synchronization reference.<br />

2. If the Tone-Clock circuit is a slave clock, then the EI to which it is<br />

listening is providing a bad timing source. Follow the diagnostic<br />

procedures specified for TDM-CLK Error Code 2305.<br />

3. S8700 series | S8500: If no problem can be found with the incoming<br />

synchronization signal, replace the IPSI or Tone-Clock circuit pack.<br />

See Replacing the IPSI or Tone-Clock Circuit Pack.<br />

2 FAIL The Tone-Clock circuit has inaccurately detected loss of signal on the<br />

incoming synchronization timing source.<br />