x. Error Types 3585 to 3601: for later releases of G3V4 <strong>and</strong> beyond, Error Type 3585 shows<br />

that this board is receiving misframes. The AUX Data contains the last misframe count<br />

reported.<br />

y. Error Type 3840: not service-affecting. No action is required. These <strong>error</strong>s are reported by<br />

the circuit pack when it receives a bad control chel message from the switch. The auxiliary<br />

data identifies the following <strong>error</strong> events:<br />

Aux Data Event<br />

4096 Bad major heading<br />

4097 Bad port number<br />

4098 Bad data<br />

4099 Bad sub-qualifier<br />

4100 State inconsistency<br />

4101 Bad logical link<br />

z. Error Type 3841: the UDS1 Interface circuit pack has detected a transient hardware logic<br />

<strong>error</strong> (for example, program logic inconsistency). This <strong>error</strong> will disappear when no faults<br />

are detected for 100 minutes. The value in Aux Data indicates the type of hardware<br />

problem.<br />

aa. Error Type 3842: bad translation RAM location found <strong>error</strong>. This <strong>error</strong> is not<br />

service-affecting. No action is required. A Bad Translation RAM is detected, but the call<br />

continues by using another translation location.<br />

ab. Error Type 3843: LAN Receive Parity Error. This <strong>error</strong> occurs when the circuit pack detects<br />

an <strong>error</strong> in a received frame from the Packet bus. These <strong>error</strong>s are most likely caused by a<br />

Packet bus problem, but may be due to a circuit pack fault.<br />

See PKT-INT (Packet Interface) to determine whether the problem is isolated to this circuit<br />

pack or is caused by Packet bus faults.<br />

ac. Error Type 3900: provides status information about a CPE Loopback Jack <strong>test</strong>. The value<br />

in the Aux Data field indicates the status of the loopback <strong>test</strong>.<br />

Aux Data Test Status<br />

1 Test is currently running<br />

2 Failed because loopback could not be activated<br />

3 Failed because <strong>test</strong> pattern could not be detected<br />

4 Test has been terminated<br />

1038 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers