ATM Crosstalk Test (#1298)<br />

ATM Crosstalk Test (#1298)<br />

The ATM Crosstalk Test verifies that TDM time slots are correctly allocated to connections. It is<br />

useful for diagnosing one-way or noisy connections. The <strong>test</strong> fails if the TDM programmable<br />

logic <strong>and</strong>/or the interface to the DSP is not operating properly.<br />

This <strong>test</strong> runs on ATM-EI (Expansion Interface Circuit Pack) <strong>and</strong> ATM-TRK (Circuit Emulation<br />

Service Circuit Pack).<br />

Note: This<br />

Note:<br />

<strong>test</strong> takes approximately 12 minutes <strong>and</strong> applies only to TN2305 <strong>and</strong><br />

TN2306 circuit packs.<br />

Table 510: ATM Crosstalk Test (#1298) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong>. The system may<br />

be under heavy traffic conditions, or it may have time slots<br />

out-of-service due to TDM-BUS <strong>error</strong>s. A system is considered under<br />

heavy traffic when the Call Processing Occupancy is greater than<br />

50% or when the System Management <strong>and</strong> the Call Processing<br />

Occupancies together exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display <strong>error</strong>s <strong>and</strong> resolve any TDM-BUS (TDM Bus)<br />

<strong>error</strong>s.<br />

3. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1003 ABORT The system could not allocate a tone receiver for the <strong>test</strong>. The system<br />

may be oversized for the number of Tone Detectors present, or some<br />

Tone Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see<br />

information regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) <strong>error</strong>s.<br />

3. Resolve any TONE-PT (Tone Generator) <strong>error</strong>s.<br />

4. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />