Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

This <strong>test</strong> runs on DIG-IP-S (Digital IP Station) <strong>and</strong> H323-STN (H.323 IP Station).<br />

..<br />

Table 519: Signaling Path PING Test (#1373)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore.<br />

1427 ABORT This <strong>test</strong> does not apply to OPTIM stations. This <strong>error</strong> can be ignored.<br />

2100 ABORT Could not locate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals, up to 3 times.<br />

1003 FAIL Ping to the destination failed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals, up to 3 times.<br />

2. Investigate any C-LAN Ethernet port <strong>error</strong>s.<br />

1007 FAIL The system could not PING the registered endpoint via the C-LAN.<br />

1. Verify that at least one destination reachable through this port. PING<br />

this destination (ping ip-address xxx.xxx.xxx.xxx).<br />

2. If the PING to any destination is successful through this port, the link<br />

is up.<br />

3. If the PING to every destination fails, <strong>test</strong> the C-LAN port using <strong>test</strong><br />

port location, <strong>and</strong> follow the repair procedures for Session<br />

Status Test (#1286) failures.<br />

4. If only this station cot be pinged:<br />

● Make sure the PC is up.<br />

● Make sure the PC has a network connection (Ethernet or dial-up).<br />

● Check the Ethernet cabling.<br />

PASS The system can successfully send IP packets to the registered endpoint<br />

from the C-LAN.<br />

1650 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers