Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 398: Hook State Inquiry Test (#566) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Any FAIL Internal system <strong>error</strong>. This <strong>test</strong> should never fail.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2. If the <strong>test</strong> continues to fail, reset the circuit pack.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

4. If the <strong>test</strong> continues to fail, escalate the problem.<br />

PASS The system <strong>and</strong> the Maintenance/Test analog port agree on the<br />

Maintenance/Test analog port hook state.<br />

Packet Bus Port Health Inquiry Test (#567)<br />

This <strong>test</strong> verifies that the packet bus fault-detection <strong>and</strong> maintenance function of the M/T-PKT is<br />

functioning properly. This is done by having the M/T-PKT perform a self-<strong>test</strong>. If the self-<strong>test</strong><br />

passes, then the Packet Bus Port Health Inquiry <strong>test</strong> passes. If the self-<strong>test</strong> fails or<br />

Communication Manager cot communicate with the M/T-PKT, then the <strong>test</strong> fails.<br />

This <strong>test</strong> runs on M/T-PKT (Maintenance/Test Packet Bus Port).<br />

Table 399: Packet Bus Port Health Inquiry Test (#567) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT System resources necessary to run this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2500 ABORT An internal operation failed, <strong>and</strong> the <strong>test</strong> could not be completed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1368 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 2<br />

1 of 2