d. Error Type 130: the circuit pack has been removed or has been insane for more than 11<br />

minutes. To clear the <strong>error</strong>, reinsert or replace the circuit pack.<br />

e. Error Type 257: the EPF has been turned off due to an overcurrent condition at the voice<br />

terminal. Check for defective wiring or a damaged jack, <strong>and</strong> verify that the voice terminal is<br />

an MET set. Once the problem is resolved, the system retires the alarm after a<br />

predetermined time delay.<br />

f. Error Type 513: the EPF inquiry audit has returned “epf-no-load” messages. This usually<br />

indicates that the voice terminal has been disconnected or that there is a defect in the wiring<br />

to the terminal. Check out both possibilities.<br />

When the EPF inquiry audit subsequently receives an “epf-on-ok” or an “epf-off-ok”<br />

message, the system will take action to retire the alarm.<br />

g. Error Type 1537: the port has reported a problem with the data link to the voice terminal.<br />

Ignore this <strong>error</strong> if there are no complaints about the voice terminal. Otherwise, make sure<br />

the voice terminal is connected, check for defective wiring, check for a defective voice<br />

terminal, <strong>and</strong> decrease the length of the wiring between the voice terminal <strong>and</strong> the switch. If<br />

the problem persists, replace the circuit pack.<br />

h. Error Type 2049, Aux Data 32770: the voice terminal went off-hook while it was in the<br />

ready-for-service state. Use status station to determine the state of the voice terminal.<br />

The off-hook should have moved the station to in-service. No repair action is necessary.<br />

Error Type 2049, Aux Data 40967: this code is generated when the link between the<br />

circuit pack <strong>and</strong> the voice terminal is successfully reset. No repair action is necessary.<br />

i. Error Type 3840: the hardware sent an uplink message indicating that the Electric Power<br />

Feed (EPF) is not loaded, that is, it is not currently supplying power to a voice terminal. No<br />

repair action is necessary.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

624 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

NPE Crosstalk Test (#6) X ND<br />

Port Diagnostic Test (#35) X ND<br />

Analog Electronic Power Feed Test (#56) X ND<br />

Hybrid Circuit <strong>and</strong> Conference Circuit Test (#57) X ND<br />