Table 452: DS1 Facilities Connectivity Loopback Test (#790) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

DS1 Facilities Connectivity Test (#790)<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

FAIL TN574 DS1 facilities connectivity loopback <strong>test</strong> failed.<br />

For the following failures, see the repair procedures for Error Code 55.<br />

1 FAIL TN1654 near-end DS1 facility A is connected to far-end DS1 facility B.<br />

2 FAIL TN1654 near-end DS1 facility A is connected to far-end DS1 facility C.<br />

3 FAIL TN1654 near-end DS1 facility A is connected to far-end DS1 facility D.<br />

10 FAIL TN1654 near-end DS1 facility B is connected to far-end DS1 facility A.<br />

12 FAIL TN1654 near-end DS1 facility B is connected to far-end DS1 facility C.<br />

13 FAIL TN1654 near-end DS1 facility B is connected to far-end DS1 facility D.<br />

20 FAIL TN1654 near-end DS1 facility C is connected to far-end DS1 facility A.<br />

21 FAIL TN1654 near-end DS1 facility C is connected to far-end DS1 facility B.<br />

23 FAIL TN1654 near-end DS1 facility C is connected to far-end DS1 facility D.<br />

30 FAIL TN1654 near-end DS1 facility D is connected to far-end DS1 facility A.<br />

31 FAIL TN1654 near-end DS1 facility D is connected to far-end DS1 facility B.<br />

32 FAIL TN1654 near-end DS1 facility D is connected to far-end DS1 facility C.<br />

2 of 3<br />

Issue 5 May 2009 1509

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!