19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

PN Maintenance Circuit Pack<br />

Sanity Maze Test (#303)<br />

The processor on the PN’s Maintenance circuit pack has direct access to special registers in the<br />

Maintenance circuit pack. These registers are tied to such things as the Expansion Interface<br />

circuit pack reset leads <strong>and</strong> Carrier Port Power Unit reset leads which enable the PN’s<br />

Maintenance circuit pack to recycle carriers. To prevent an insane Maintenance circuit pack<br />

from inadvertently controlling these external devices, a special interface called the Sanity Maze<br />

is provided. There are two parts to the <strong>test</strong>. Part 1 involves navigating the Sanity Maze to toggle<br />

an unused lead. Part 2 attempts to toggle an unused lead without first navigating the Sanity<br />

Maze. The Sanity Maze <strong>test</strong> passes if Part 1 is successful <strong>and</strong> Part 2 fails.<br />

This <strong>test</strong> runs on MAINT (PN Maintenance Circuit Pack).<br />

Table 387: PN Maintenance Circuit Pack Sanity Maze Test (#303)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2033 ABORT Internal <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL The Sanity Maze of the PN’s Maintenance circuit pack is defective.<br />

1. Replace the PN’s Maintenance circuit pack.<br />

PASS The Sanity Maze is working properly, <strong>and</strong> the PN’s Maintenance circuit<br />

pack can access the unused register. If recycle carrier for PN<br />

carriers does not work, the following problems may still exist:<br />

1. The Carrier Port Power Unit or wiring to the Carrier Port Power<br />

Unit may be defective. See CARR-POW (Carrier Power Supply).<br />

2. Since this <strong>test</strong> only <strong>test</strong>s the PN, there is a very small probability<br />

that the PN’s Maintenance circuit pack cot access those registers<br />

that deal with PN devices. The Maintenance circuit pack may need<br />

to be replaced.<br />

1346 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers