Note: An<br />

Note:<br />

out-of-tolerance voltage condition may be caused by transient conditions (e.g.<br />

board insertion or electrical noise). Voltage problems can cause serious damage<br />

to the TN2314 or highly unpredictable failure modes. Therefore, a repeating<br />

condition will cause a major alarm. The following Error Types 769 through 1793<br />

represents the various system voltages <strong>and</strong> are listed below:<br />

e. Error Type 769: Out-Of-Tolerance voltage condition for -48 VDC.<br />

f. Error Type: 1025: Out-Of-Tolerance voltage condition for -5 VDC.<br />

g. Error Type: 1281: Out-Of-Tolerance voltage condition for +5 VDC.<br />

h. Error Type: 1537: Out-Of-Tolerance voltage condition for +12 VDC.<br />

i. Error Type: 1793: Out-Of-Tolerance voltage condition for +3.3 VDC.<br />

248 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers