Procedures for Restoring the PMS Link<br />

PMS-LINK (Property Management System Link)<br />

1. Determine the status of the PMS Link.<br />

Enter status pms-link, <strong>and</strong> make sure that the PMS Link is not busied out for<br />

maintenance. If the link is “down,” then continue with the next step.<br />

2. Where does the PMS Link connect?<br />

Enter display system-parameters hospitality, <strong>and</strong> find out the destinations of<br />

the PMS Link.<br />

3. Determine the status of the data extension.<br />

Enter status data extension, <strong>and</strong> verify whether the data extension is in the<br />

in-service/idle state. If the data extension is not available, then look for the extension<br />

number in Alt Name field of the Error Log. See XXX-BD (Common Port Circuit Pack/<br />

Media Module) for resolutions.<br />

4. Is the external PMS device available?<br />

Make sure that the PMS device is ON-LINE <strong>and</strong> ready for service. Check the physical<br />

connectivity between Data Module <strong>and</strong> the PMS device.<br />

5. If the problem is not found in the above steps, check the C-LAN board for any problems.<br />

For a description about the C-LAN board <strong>and</strong> its connectivity, refer to Downloading<br />

License <strong>and</strong> Authentication files from RFA in Maintenance Procedures for <strong>Avaya</strong> Aura<br />

Communication Manager, Media Gateways <strong>and</strong> Servers (03-300432).<br />

When restoring the PMS link, it is necessary to execute maintenance <strong>test</strong> on different objects<br />

that comprise the PMS link. It is recommended that you busyout the PMS link before trying to<br />

restore the link. When the PMS Link is busied out, every PMS Link maintenance action is<br />

deactivated, <strong>and</strong> interference with <strong>test</strong>s of other MOs is prevented.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 210: PMS-LINK Error Log Entries 1 of 2<br />

Error Type Aux Data Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> pms-link<br />

18 (b) 0 busyout<br />

pms-link<br />

257 (c) Any Link Retry <strong>test</strong><br />

(#215)<br />

WRN OFF release pms-link<br />

MIN OFF <strong>test</strong> pms-link l<br />

WRN1 513 (d) Any <strong>test</strong> pms-link<br />

1 of 2<br />