Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 538: Verify NIC Options Test (#1511) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1014 ABORT Board is not inserted.<br />

1. Enter list configuration board to ensure that the circuit pack<br />

is inserted in the carrier.<br />

2. If the board is not inserted, make sure the circuit pack is inserted in<br />

the carrier <strong>and</strong> fully seated.<br />

1022 ABORT Invalid board. The board is not capable of changing its Ethernet options.<br />

1115 ABORT Unable to allocate system resources to run this <strong>test</strong>.<br />

1. Retry the <strong>test</strong> at one minute intervals up to a maximum of 3 times.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the time allowed. Retry the<br />

comm<strong>and</strong> at 1 minute intervals a maximum of 3 times.<br />

1. If this result occurs repeatedly, attempt to reset the circuit pack.<br />

2. Rerun the <strong>test</strong>. If this result occurs again after resetting the board,<br />

replace the circuit pack.<br />

2012<br />

2100<br />

2500<br />

ABORT Internal system <strong>error</strong>.<br />

System resources required for this <strong>test</strong> are not available.<br />

Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2801 ABORT Could not find the IP address for this board.<br />

1. Enter change ip-interfaces location to administer an IP<br />

address for this board.<br />

2. Rerun the <strong>test</strong>.<br />

2807 ABORT The board is administered but not enabled on the ip-interfaces form.<br />

1. Enter change ip-interfaces location to enable the board.<br />

2. Rerun the <strong>test</strong>.<br />