Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 432: St<strong>and</strong>by Reference Health Check Test (#651)<br />

Error<br />

Code<br />

0<br />

1<br />

Test<br />

Result<br />

FAIL<br />

FAIL<br />

Description / Recommendation<br />

Tie Trunk Dial Test (#747)<br />

The external synchronization timing source for side A of the Stratum-3<br />

clock or for the primary DS1 reference is either absent or invalid. The<br />

external synchronization timing source for side B of the Stratum-3 clock or<br />

the secondary DS1 reference is not yet <strong>test</strong>ed.<br />

The external synchronization timing source for side B of the Stratum-3<br />

clock or for the secondary DS1 reference is either absent or invalid.<br />

1. Correct the synchronization source problem. See SYNC (Port<br />

Network Synchronization).<br />

2. If the <strong>error</strong> still exists, replace the IPSI or Tone-Clock circuit pack<br />

reported in the <strong>error</strong> log. See Replacing the IPSI or Tone-Clock<br />

Circuit Pack.<br />

PASS The external synchronization timing source is valid.<br />

This <strong>test</strong> performs a dial tone/seizure <strong>test</strong> on a 2W LD tie trunk port. It seizes a trunk <strong>and</strong><br />

outpulses a pause digit. It aborts on ports administered as access endpoints.<br />

This <strong>test</strong> runs on TIE-TRK (Analog Tie Trunk).<br />

Table 433: Tie Trunk Seizure Test (#747) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1442 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />