Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

The PN’s Maintenance circuit pack has 3 separate serial interfaces, one to each of the<br />

following:<br />

● Management terminal - <strong>test</strong>ed by Test #228<br />

● Active EI circuit pack - <strong>test</strong>ed by Test #229<br />

● St<strong>and</strong>by EI circuit pack - <strong>test</strong>ed by Test #229<br />

A request is sent to the PN’s Maintenance circuit pack over the active link. If a response is<br />

received, the serial interface circuitry associated with the active link is working properly.<br />

This <strong>test</strong> runs on MAINT (PN Maintenance Circuit Pack).<br />

Table 372: Serial Chel Local Looparound Test (#229) 1 of 2<br />

Error<br />

Code<br />

1000<br />

2000<br />

2033<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT System resources required to run this <strong>test</strong> are not available.<br />

Response to the <strong>test</strong> was not received within the allowed time.<br />

Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times<br />

2034 ABORT The SAT port is busy. Background maintenance may be running.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2500 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times<br />

1306 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />