Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 295: Tone Generator Transmission Test (#40) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT The system was not able to allocate all the resources needed for this<br />

<strong>test</strong> or there was an Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 ABORT The system could not allocate all the resources needed to <strong>test</strong> the<br />

DTMF tones.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1001 ABORT The system was not able to put the tone generation facility in the<br />

appropriate mode to <strong>test</strong> it.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong> connection. This<br />

can happen when the system is heavily loaded.<br />

1. If the system is not heavily loaded, <strong>test</strong> the TDM bus with<br />

<strong>test</strong> tdm port-network P.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1003 ABORT The system could not allocate a tone receiver for the <strong>test</strong>. The system<br />

may be oversized for the number of Tone Detectors present, or some<br />

Tone Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see<br />

information regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) <strong>error</strong>s.<br />

3. Resolve any TONE-PT (Tone Generator) <strong>error</strong>s.<br />

4. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1022 ABORT Tone detection for the system is administered as wide broadb<strong>and</strong> (tone<br />

detection mode 5), <strong>and</strong> the Tone Detector used for this <strong>test</strong> was not a<br />

TN420C (the only circuit pack with this capability). GPTD ports on other<br />

types of Tone Detector circuit packs are taken out of service since they<br />

cot provide the administered function. Either:<br />

● Change the tone-detection mode administered on the<br />

system-parameters country-options screen.<br />

● Remove all non-TN420C circuit packs from the system.<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore<br />