19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

● SNI-BD (SNI Circuit Pack)<br />

● SNI-PEER (SNI Peer Link)<br />

Table 445: Failure Audit Test (#777) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

2300 The downlink message necessary to run this <strong>test</strong> could not be sent.<br />

2301 The timer could not be set before sending the downlink message.<br />

2302 The SNI circuit pack received a bad message from software.<br />

2303 Test requested by software is invalid.<br />

2304 SNI firmware is not able to run the <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1490 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

1 of 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!