MG-IAMM (Integrated Analog Media Module)<br />

MG-IAMM (Integrated Analog Media Module)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

MG-IAMM MIN <strong>test</strong> board location long Integrated Analog<br />

Media Module<br />

The MG-IAMM Maintenance Object resides on the Integrated Analog Media Module (IAMM)<br />

which is located on the main board of the G250, G250-BRI, G250-DCP, G250-DS1, G350, <strong>and</strong><br />

TGM550 media gateways.<br />

The Integrated Analog Media Module is not field-replaceable.<br />

For the G250, the Integrated Analog Media Module consists of six (6) fixed configuration analog<br />

ports:<br />

● Ports 1 through 4 are fixed as loop start CO trunk ports.<br />

● Ports 5 <strong>and</strong> 6 may be administered as analog stations, DID trunks, or external alarm ports.<br />

● Ports 4 <strong>and</strong> 5 are used by the media gateway processor for emergency transfer relay<br />

(ETR) purposes.<br />

The Integrated Analog Media Module is a non-field-replaceable module. Slot #3 is virtual <strong>and</strong><br />

designated as the integrated analog media module slot. Slot #3 supports the IAMM exclusively.<br />

For the G250-BRI <strong>and</strong> G350, the Integrated Analog Media Module consists of three (3) fixed<br />

configuration analog ports:<br />

● Port 1 is fixed as an analog trunk port.<br />

WRN <strong>test</strong> board location<br />

● Ports 2 <strong>and</strong> 3 are fixed as analog line ports.<br />

● Ports 1 <strong>and</strong> 2 are used by the media gateway processor for emergency transfer relay<br />

(ETR) purposes.<br />

On a G250-BRI, slot #3 is virtual <strong>and</strong> designated as the integrated analog media module slot.<br />

On a G350, slot #7 is virtual <strong>and</strong> designated as the integrated analog media module slot.<br />

Administration will only allow port one to be administered as a loop start CO trunk. Ports 2 <strong>and</strong> 3<br />

may only be administered as analog stations, DID trunks, or external alarm ports. Ports 1 <strong>and</strong> 2<br />

are used by the emergency transfer relay (ETR).<br />

The TGM550 is the Media Gateway blade which is integrated with the Juniper Networks<br />

Services Routers. It provides an internal interface to the Juniper chassis backplane, 2 analog<br />

lines, <strong>and</strong> 2 analog trunks. Ports 2 <strong>and</strong> 3 are used by the emergency transfer relay (ETR).<br />

The G250-DCP allows 4 trunks <strong>and</strong> 2 analog lines. Ports 4 <strong>and</strong> 5 are used by the ETR.<br />

The G250-DS1 allows 1 trunk <strong>and</strong> 2 analog lines. Ports 1 <strong>and</strong> 2 are used by the ETR.<br />

See XXX-BD (Common Port Circuit Pack/Media Module) for media module level <strong>error</strong>s.<br />

Issue 5 May 2009 645