Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 284: Battery <strong>and</strong> Power Supply Query Test (#5) 4 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

4 FAIL DC-powered cabinet: The PN’s Maintenance circuit pack is<br />

incorrectly reporting a problem with power. Replace the suspect circuit<br />

pack <strong>and</strong> run the <strong>test</strong> again.<br />

AC-powered cabinet: The battery is currently being charged.<br />

1. After 30 hours, the battery should be fully charged, <strong>and</strong> this <strong>error</strong><br />

should clear.<br />

2. If after 30 hours the battery is still in the high charge rate, an<br />

alarm will be raised. Enter display <strong>error</strong>s to display the Error<br />

Log, <strong>and</strong> select the category “environs” to show only<br />

environment-related <strong>error</strong>s. Look for POWER <strong>error</strong>s of type 257.<br />

The first occurrence of this <strong>error</strong> indicates the time when the<br />

battery started charging. Use this time as the starting point to<br />

determine whether the battery has been charging for 30 hours. If<br />

so, replace the battery <strong>and</strong> battery charger.<br />

CAUTION: Read<br />

! CAUTION:<br />

the section, Replacing the Battery <strong>and</strong> Battery<br />

Charger (J58890CE) before proceeding.<br />

3. Rerun the <strong>test</strong>. If the <strong>test</strong> still fails, the PN’s MAINT (Maintenance)<br />

circuit pack could be reporting this condition incorrectly. There are<br />

failures that can occur on the PN’s Maintenance circuit pack that<br />

will not be detected by their respective maintenance, but which<br />

will cause many, if not every, environment <strong>test</strong> to fail. If many<br />

environment <strong>test</strong>s are failing, the suspect circuit pack, depending<br />

on the system configuration, should be replaced <strong>and</strong> the <strong>test</strong><br />

rerun. Resolve every alarm on these MOs, <strong>and</strong> rerun the <strong>test</strong>.<br />

6 FAIL DC-powered cabinet: The PN’s Maintenance circuit pack is<br />

incorrectly reporting a problem with power. Replace the suspect circuit<br />

pack <strong>and</strong> run the <strong>test</strong> again.<br />

AC-powered cabinet: This indicates that Error Codes 2 <strong>and</strong> 4<br />

occurred. Refer to these <strong>descriptions</strong>. Also, refer to this <strong>test</strong>’s<br />

description for Error Code 14.<br />

1080 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />