19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Variable-Speed Fans<br />

A variable-speed fan is identified by the following features:<br />

● A fan <strong>and</strong> air filter assembly with product code ED-67077-30, Group 4 or greater, labeled<br />

on the front of the carrier<br />

● A 5-pin white connector mounted next to each fan on the fan assembly cover plate for<br />

speed control <strong>and</strong> alarm circuitry<br />

● A 2-pin black -48 V power connector to each fan<br />

● A power filter (ED-1E554-30, G1 or G2) located in a metal box mounted behind the fans on<br />

the right-h<strong>and</strong> cable trough as you face the rear of the cabinet<br />

● The AHD1 circuit pack <strong>and</strong> the two S4 sensors used with older fan assemblies are absent.<br />

Alarm leads from each fan are tied together into a single lead that registers a minor alarm<br />

against CABINET whenever a fan’s speed drops below a preset limit or fails altogether.<br />

Note: The<br />

Note: Fan/filter<br />

Note:<br />

front fans may run at a different speed than the rear fans since they are<br />

controlled by different sensors.<br />

Note:<br />

replacement procedures for the CMC1 <strong>and</strong> G600 media gateways are<br />

to be found under Variable-speed fans Maintenance Procedures for <strong>Avaya</strong><br />

Aura Communication Manager, Media Gateways <strong>and</strong> Servers (03-300432).<br />

Error log entries <strong>and</strong> recommended actions<br />

S8700 Series | S8500<br />

Table 68: S8700 Series | S8500: Cabinet Sensors Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 0 Any Any Any <strong>test</strong> environment location<br />

1 0 or 1 Cabinet Temperature<br />

Query (#122)<br />

257 0 or 1 Cabinet Temperature<br />

Query (#122)<br />

MIN ON <strong>test</strong> environment location r 3<br />

MAJ ON <strong>test</strong> environment location r 3<br />

246 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers

Hooray! Your file is uploaded and ready to be published.