Expansion Interface 2-Way Transmission Test (#241)<br />

Table 376: Expansion Interface 2-Way Transmission Test (#241) 3 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1033 ABORT The <strong>test</strong> cot run because the EI board is not administered or there were<br />

no other PNs administered that had its EI board in-service.<br />

ATM-EI:<br />

1. Ensure that the board is administered as ATM PNC Expansion<br />

Interface circuit pack.<br />

2. If the board is administered as ATM-EI circuit pack, then there has<br />

been some change in the ability of the ATM-EI circuit pack in the<br />

other PNs to communicate with the ATM-EI on the other end of its<br />

connection.<br />

3. Enter status port x where x is the port-network number where<br />

the board is administered. Check if both ACL <strong>and</strong> EAL are up to<br />

this board. If not, see the service procedure for SYS-LINK (System<br />

Links).<br />

4. Check the Error Log for Error Type 1281 with Aux Data 27 (board<br />

cot talk to the ATM switch). See Table 37: Error type 1281 Aux<br />

Data <strong>and</strong> repair procedures for repair procedures.<br />

5. If present, check both the ATM switch <strong>and</strong> the Communication<br />

Manager translations for consistent ATM addresses. Reset the<br />

board, <strong>and</strong> see if the problem resolves.<br />

6. Repeat Test #241. If it continues to abort with this <strong>error</strong> code,<br />

replace the board.<br />

EXP-INTF:<br />

1. Check fiber administration to insure that there is a fiber link<br />

administered to this EI circuit pack.<br />

2. If there is a fiber administered to this EI circuit pack, then some<br />

change in the status of the ability of the EI circuit pack in the other<br />

PNs to communicate with the EI or SNI circuit pack on the other<br />

end of its fiber has occurred.<br />

3. Test #237 <strong>and</strong> check for EXP-INTF circuit pack Error Type 1281 in<br />

the Error Log for the EI circuit packs in these other PNs. If Error<br />

Type 1281 is present <strong>and</strong>/or Test #237 does not pass, see repair<br />

procedures for Test #237, in Table 373: Expansion Interface<br />

Neighbor Query Test (#237).<br />

4. If Test #237 passes, reseat the EI circuit pack. This is not<br />

destructive since the circuit pack cot be serving as the Expansion<br />

Archangel if it is not in service.<br />