Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Speech Synthesis PSS H<strong>and</strong>shake Test (#168)<br />

This <strong>test</strong> verifies control functionality between the on-board microprocessor <strong>and</strong> programmable<br />

speech synthesizer (PSS) controller. A failure occurs if either of the following events occur:<br />

● The on-board microprocessor times out while waiting for the PSS controller to respond.<br />

● An invalid comm<strong>and</strong> is received by the on-board microprocessor from the PSS controller.<br />

This type of failure will affect all four ports on the Speech Synthesis circuit pack, resulting in<br />

<strong>error</strong>s or alarms on each port. This <strong>test</strong> runs on S-SYN-PT (Speech Synthesis Port).<br />

Table 356: Speech Synthesis PSS H<strong>and</strong>shake Test (#168)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The port<br />

may be busy with a valid call.<br />

1. Wait until the port is idle (amber LED is off), then retry the<br />

comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000<br />

2100<br />

ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

Any FAIL The on-board microprocessor has timed out while waiting for the PSS<br />

controller to respond or an invalid comm<strong>and</strong> has been received by the<br />

on-board microprocessor from the PSS controller. This type of failure<br />

may cause features using the Speech Synthesis port’s speech services<br />

to malfunction.<br />

1. Replace the circuit pack.<br />

PASS The on-board microprocessor/PSS h<strong>and</strong>shake is working correctly.<br />

Investigate user-reported troubles by using other <strong>test</strong>s <strong>and</strong> by verifying<br />

other ports on this circuit pack are working correctly.<br />

1274 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers