Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Angel Speech Processor H<strong>and</strong>shake Test (#208)<br />

This <strong>test</strong> checks the integrity of the communication link between the two processors on the<br />

announcement circuit pack. This <strong>test</strong> runs on -BD (Announcement circuit pack).<br />

WARNING: Failure<br />

of this <strong>test</strong> indicates that the Speech Processor is insane <strong>and</strong> results in<br />

the loss of all integrated announcements on the circuit pack.<br />

Table 362: Angel Speech Processor H<strong>and</strong>shake Test (#208)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description/ Recommendation<br />

2000 ABORT Response to the <strong>test</strong> request was not received within the time allowed.<br />

1. Check the Error Log with display <strong>error</strong>s. If Error Type 1538 is<br />

present in the Error Log, reset the circuit pack.<br />

2. Retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals a maximum of 5 times.<br />

FAIL The <strong>test</strong> failed. The circuit pack cot be used. announcement speech<br />

memory is cleared when this <strong>test</strong> fails. Therefore, when the problem has<br />

been resolved, announcements must be rerecorded or downloaded to<br />

the circuit pack.<br />

1. Reset the circuit pack via reset board location <strong>and</strong> then run<br />

this <strong>test</strong> again. If the <strong>test</strong> continues to fail, replace the circuit pack<br />

<strong>and</strong> run this <strong>test</strong> again.<br />

2. If there are recurring alarms on this circuit pack caused by this <strong>test</strong><br />

failing, replace the circuit pack even if Step 1 works.<br />

WARNING: Replacing<br />

the circuit pack results in loss of integrated<br />

announcements. See General notes.<br />

PASS The communications link between the two processors on the<br />

announcement circuit pack is functioning properly. Investigate<br />

user-reported troubles on this circuit pack using other circuit pack <strong>and</strong><br />

port <strong>test</strong>s. Refer to -PT (Announcement Port) for a description of the <strong>test</strong>s.<br />

1288 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!